Saying Goodbye but not to safety...
Anticipation...
Electronic components in railway applications have to conform with rigid safety levels, often combined with the most
rugged environmental requirements. Because of the danger to human life and high downtime costs, reliability must be
predictable, regular maintenance must not be required, batteries are not allowed etc. Thus, only the highest quality in
development and production guarantees a reliable product for an operation period of 20 years and more.
Development and therefore the supplier company must
conform to ISO 9001. During the design phase the layout
of the board and the choice of components critically
influences the suitability for operation in extended
temperature (Tx = -40 to +85°C), under shock, vibration,
humidity and chemical influence. Conformal coating as
well as high-voltage isolation is mandatory, components
must conform to EN, CECC or IEC standards, must have a
second source or must be used only in the specification
range of the data sheet (which forbids temperature
screening) for example. Electronics must provide
functions such as memory check, self test, watchdog,
error output or re-start within a short time.
Hardware and software design is carried out according to
EN 50126, EN 50128 and EN 50129 when the application
is safety-critical.
The optimum board design also anticipates the quality of
the software design and the quality in production and
testing. This requires the usage of appropriate development
tools for design and simulation. EDA tools should be
directly coupled to the manufacturing data base.
Testing prescribes type tests, routine tests and investigatory
tests. Type tests include for example low temperature,
dry heat, humid heat cycles, over-voltage, electromagnetic
immunity, radiation, isolation, salt fog, shock and vibration
etc.
MEN maintains its own laboratory with a climatic cham-
ber, EMC chamber and shaker for pre-qualification and
cooperates with LGA (Landesgewerbeanstalt Nürnberg)
to achieve official EN 50155 approval.
EN 50155 in Development
and Qualification